Rapid antigen tests for the diagnosis of a SARS-CoV-2 infection
Welcome! On this webpage we try to summarize the results of manufacturer independent evaluations of antigen detecting rapid diagnostic tests (Ag-RDTs) for SARS-CoV-2.
Background: Since the beginning of the COVID-19 pandemic, numerous Ag-RDTs have appeared on the market. On their homepage, the Federal Institute for Drugs and Medical Devices (BfArM) provides a list of Ag-RDTs [1] which fulfill certain minimum requirements. These requirements were jointly determined by the Paul-Ehrlich-Institute (PEI) and Robert-Koch-Institute (RKI) to include a sensitivity of >70% and a specificity >97% [2].
Manufacturer independent evaluations are important to provide an objective assessment of a test’s accuracy. Thus far only evaluations by the tests’ manufacturers themselves are summarized. Therefore, on this webpage we try to give an overview on the data published by manufacturer independent researchers. Using the linked calculator, it is also possible to convert the shown sensitivity and specificity into the concrete amount of true and false test results.
| Manufacturer, Test | Sensitivity (CI 95%) | Specificity (CI 95%) | Ease of use | Risk of bias1 | Study location | Independence2 | Source |
|---|---|---|---|---|---|---|---|
| Abbott, Panbio* | 85.5% (78.0-91.2) 91.7% (89.8-93.4) 79.6% (67.0-88.8) 73.3% (62.2-83.8) 75.5% (69.5-81.5) 86.8% (79.0-92.0) 72.6% (64.5-79.9) 81.0% (69.0–89.8) 71.4% (63.1-78.7) 86.1% (78.6-91.7) 90.5% (87.5–93.6) 66.4% (59.9-72.2) 60.8% (46.1–74.2) 48.1%3 (37.4-58.9) 44.6% (34.3-55.3) | 100% (99.1-100) 98.9% (97.5-99.6) 100% (98.7-100) 100% (not provided) 94.9% (91.2-98.6) 99.9% (99.4-100) 100% (99.7-100) 100% (99.7-100) 99.8% (99.4-99.9) not provided 98.8% (98.0–99.7) 100% (99.0 – 100) not provided 100% (99.3-100) 100% (96.3 – 100) | N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A | low concern intermediate concern low concern intermediate concern low concern low concern low concern low concern low concern low concern intermediate concern low concern high concern low concern intermediate concern | Switzerland Spain Spain Spain France Germany Netherlands Aruba Spain Switzerland Spain Czech Republic Austria Spain Germany | yes yes no yes yes yes yes yes yes yes no yes yes no unclear | [10] [21] [23] [24] [28] [35] [33] [33] [38] [39] [40] [42] [45] [47] [53] |
| SD Biosensor / Roche, Standard Q* | 76.6% (62.8-86.4) 89.0% (83.7-93.1) 88.7% (81.3-93.4) 70.6% (not provided) 81.8% (71.3-89.6) 92.9% (86.4-96.9) 84.9% (79.1-89.4) 70.7% (not provided) 70% (not provided) 71.7% (not provided) 49.4% (38.9-59.9) 80.3% (74.9-85.4) | 99.3% (98.-99.6) 99.7% (98.4-100.0) 97.6% (95.2-98.8) 100% (not provided) 99.6% (97.8-99.9) not provided 99.6% (98.6-99.9) 96% (not provided) 92% (not provided) 99.5% (not provided) 100% (96.3 – 100) 99.1% (98.6–99.3) | very good N/A to come N/A N/A N/A N/A N/A N/A N/A N/A N/A | low concern low concern low concern low concern low concern low concern low concern intermediate concern high concern low concern intermediate concern intermediate concern | Germany and England Switzerland Brasil Italy India Switzerland Netherlands Germany Uganda Germany Germany Italy | yes yes yes yes yes yes yes unclear yes yes unclear unclear | [6], [11] [10] [11] [25] [30] [39] [41] [43] [46] [51] [53] [57] |
| AAZ, COVID-VIRO | 96.7% (93.5-99.9) 84.1% (76.9-89.7) | 100% (not provided) not provided | N/A N/A | low concern low concern | France Switzerland | unclear yes | [20] [39] |
| Bionote, NowCheck | 89.2% (81.7-93.9) | 97.3% (94.8-98.6) | N/A | low concern | Brasil | yes | [34] |
| Coris, Respi-Strip | 50.0% (21.5-78.5) 50.0% (39.5-60.5) 30.2% (21.7-39.9) 30.0% (16.7-47.9) | 95.9% (93.5-97.4) 100% (91.8-100) 100% (not provided) 100% (not provided) | insufficient N/A N/A N/A | low concern intermediate concern low concern low concern | Germany and England France Belgium Belgium | yes unclear no yes | [6] [12] [26] [27] |
| Denka, QuickNavi | 86.7% (78.6-92.5) | 100% (99.7-100) | N/A | low concern | Japan | no | [60] |
| Fujirebio, LUMIPULSE | NP: 81.6% (71-89.5) saliva: 41.3% (30.4-52.8) | NP: 93.8% (86.2-98) saliva: 98.6% (95-99.8) | N/A N/A | low concern low concern | Italy Italy | yes yes | [59] [59] |
| MEDsan, SARS-Cov-2 Antigen Tests | 45.8% (35.5-56.5) | 97.0% (91.5 – 98.9) | N/A | intermediate concern | Germany | unclear | [53] |
| Nal von Minden, NADAL | 73.1% (not provided) | (not provided) | N/A | high concern | Germany | no | [58] |
| Quidel, Sofia SARS Antigen FIA | 93.8% (79.9-98.3) 77.0% (not provided) | 100% (87.5-100) 99.6% (not provided) | N/A N/A | high concern low concern | Chile United States | yes unclear | [22] [43] |
| RapiGen, Biocredit | 74.4% (65.8-81.4) 52.0% (33.5-70.0) 62.0% (51.0-71.9) 85% (not provided) 48.1% (not provided) | 98.95% (97.2-99.6) 100% (99.7-100) 100% (88.7-100) 100% (not provided) not provided | to come very good N/A N/A N/A | low concern low concern high concern low concern high concern | Brasil Germany Chile Nepal Egypt | yes yes no unclear yes | [7] [8] [14] [32] [49] |
| R-Biopharm, RIDA QUICK | 77.6% (not provided) 50% (not provided) | 100% (not provided) 100% (not provided) | N/A N/A | low concern low concern | Germany Germany | no no | [54] [54] |
| SD Biosensor, Standard F | 69.2% (53.5-81.4) 77.5% (69.2-84.1) 90.6% (75.8-96.8) 47.1% (37.1-57.1) 62.3% (55.8-68.4) | 96.9% (95.2-98.0) 97.9% (95.7-99.0) 100% (87.5-100) 98.4% (96.0-99.6) 99.5 (98.0-99.9) | very good to come N/A N/A N/A | low concern low concern high concern low concern low concern | Germany Brasil Chile Italy Czech Republic | yes yes yes yes yes | [8] [9] [22] [29] [42] |
| Shenzen Bioeasy, FIA | 66.7% (41.7-84.4) 93.9% (86.5-97.4) 85.0% (75.6-91.2) | 93.1% (91.0-94.8) 100% (92.1-100) 100% (89.0-100) | good N/A N/A | low concern intermediate concern high concern | Germany and England Chile Chile | yes yes no | [6] [13] [14] |
| Siemens, CLINITEST | 54.9% (43.4-65.9) | 100% (96.3 – 100) | N/A | intermediate concern | Germany | unclear | [53] |
2 The criteria ‘independence’ evaluates if the study was conducted withoud any incluence by the test’s manufacturer. Further information can be found in the methods and sources section.
3 This study was conducted in a setting where the SARS-CoV-2 postive cases are expected to have a very low viral lode. Thus, the given sensitivity might not be a fair representation of the test’s general accuracy.
* These tests have already been recommended by the WHO.
Follow this link to get to the methods and sources section.
Furthermore, the Paul-Ehrlich-Institute has published a list of Ag-RDTs that they consider to perform to the state of the art. The list can be found following this link.
In addition to the evaluation of Ag-RDTs, we would also like to call attention to further research relevant to this topic.
Correlation of antigen and RNA concentrations:
- Pollock, N.R., et al., Correlation of SARS-CoV-2 nucleocapsid antigen and RNA concentrations in nasopharyngeal samples from children and adults using an ultrasensitive and quantitative antigen assay. medRxiv. 2020. [36]
Performance of Ag-RDTs in a high-temperature enviroment
- Haage, V., et al., Impaired performance of SARS-CoV-2 antigen-detecting rapid tests at elevated temperatures. medRxiv. 2021. [61]
Teststrategies:
- Larremore, D.B., et al., Test sensitivity is secondary to frequency and turnaround time for COVID-19 surveillance. medRxiv. 2020. [15]
- van Beek, J., et al., From more testing to smart testing: data-guided SARS-CoV-2 testing choices. medRxiv. 2020. [16]
- Paltiel, A.D., Zheng, A. und Walensky, R.P., Assessment of SARS-CoV-2 screening strategies to permit the safe reopening of college campuses in the United States. JAMA network open 3.7. 2020. [17]
- Pavelka, M., et al., The effectiveness of population-wide, rapid antigen test based screening in reducing SARS-CoV-2 infection prevalence in Slovakia. medRxiv. 2020. [48]
Alternative sampling-methods:
- Lindner, A.K., et al., Head-to-head comparison of SARS-CoV-2 antigen-detecting rapid test with self-collected anterior nasal swab versus professional-collected nasopharyngeal swab. medRxiv. 2020. [18]
- Lindner, A.K., et al., Head-to-head comparison of SARS-CoV-2 antigen-detecting rapid test with professional-collected anterior nasal versus nasopharyngeal swab. medRxiv. 2020. [52]
Evaluation of the Abbott, Panbio in a low prevalence setting for monitoring:
- Winkel, B.M.F., et al., Screening for SARS-CoV-2 infection in asymptomatic individuals using the Panbio COVID-19 Antigen Rapid Test (Abbott) compared to RT-qPCR. medRxiv. 2020. [50]
Economic modelling:
- Atkeson, A., et al., Economic Benefits of COVID-19 Screening Tests. medRxiv. 2020. [19]
- Du, Z., et al., Comparative cost-effectiveness of SARS-CoV-2 testing strategies. Researchgate. 2020. [31]
Get new content delivered directly to your inbox.